Partial Filled Pipe Magnetic Flow Meter

RBEF-P Type Partial filled electromagnetic flow meter is a flow automatic measuring instrument use for continuous measurement in open pipeline(half pipe sewage or mass flow pipe with none down flow weir) by velocity-area method. It can measure and display instantaneous flow rate, flow velocity, accumulated flow rate and any other data. It’s specially applicable to the measurement of municipal rainwater、sewage water、waste water and irrigation water. 

 


 


 

 

 

Description

  • Principle
  • Features
  • Specification
  • Model Selection
  • Applicants
  • Download
Principle
Features

RBEF-P Type Partial filled Electromagnetic Flow Meter(EMF) Features:

  • Nominal diameter range: DN100~DN1200;

  • Measurement accuracy:+ 2.5%FS, accurately measure the flow rate between 10% and 100% of the liquid level;
  • The measurement range is large, and the flow measurement is not affected by backwater of the tributary surface,
  • Multiple connection methods: GB, DIN, ANSI, installation length in accordance with ISO standard.
  • It is not affected by floating objects, sediment and bubbles in the water during measurement, and the flow sensor has little resistance to the water flow, with simple structure, compact dimensions, and easy installation 
  • Standard pipelines can be installed directly without transformation, and the installation and construction cost is low:
  • The electrodes are installed at 10%, 30% and 50% of the pipeline diameter and will be automatically chosen to calculate the flow velocity , so it will not be affected by the grease floating on the liquid surface,
  • Small blind zoom, high-precision level gauge;
  • Split converter: suitable for detached installation required by column or wall mounting.The instrument display and output function are various, which can display measurement data such as water level, flow rate, flow rate. cumulative flow rate. etc..
  • Various outputs include RS485, 4-20mA, pulse output.
Specification

RBEF-P Type Partial filled Electromagnetic Flow Meter(EMF) Specification:

Measuring Pipe Size

DN100-DN1400

Connection

Flange

Liner Material

Neoprene/Others

Electrode  Material

SS316, TI, TA, HB, HC

Structure Type

Remote Type

Accuracy

2.50%

Output Signal

Modbus RTU, TTL electrical level

Communication

RS232/RS485

Flow speed range

0.05-10m/s

Protection Class

Converter: IP54

 

Flow Sensor: IP65(standard), IP68(optional)

 Display:



 Instantaneous flow, total flow, flow velocity, liquid level, etc.
Model Selection

RBEF-P Type Partial filled Electromagnetic Flow Meter(EMF) Selection:

 

RBEF Electromagnetic Flow Meter Model Selection
RBEF  
    [1]      [2]  [3] [4]     [5] [6]   [7] [8] [9] [10]   [11]       [12] [13]    [14]
[1] Category     Grounding & Lining Protection
F Flanged C Ceramic Mini Mini
[6]
0   Body-flange grounding  (DN15 - DN1200)
W Wafer-type S High-Frequency Ex Ex-proof 1   Ground ring [or lining protection flange] (DN15-DN250)
L Threaded B Battery-Powered I  Insertion 2 Grounding electrode   (DN25 - DN1200)
K Clamping Hp High-pressure H Energy 3   Import protection flange  (DN50 - DN300)
[2] Nominal Diameter(mm)   Ambient Temperature
003 065 400 [7] A   ≤80 ℃    (All lining)
006 080 450 B   ≤120 ℃  (Only Neoprene、PTFE、PFA)
010 100 500 C   ≤180 ℃  (Only PTFE)
015 125 600   Protection& Anti-hazard Requirement
020 150 700
[8]
1   IP65
025 200 800 2   IP67  (Only compact)
032 250 900 3 IP68  (Only remote,tie cable should be specified)
040 300 102 4   IP65+Ex d ib mb IIC T4 Gb
050 350 122   Sensor And Converter Combination Structure
E.g. :050 = DN50; 150 = DN150; 122 = DN1200 [9] C   Compact(Only DN15-DN1000)
[3] Nominal Pressure& Process Connection R   Remote(With 10m signal cable, the other length
  is set separately)
02    0.25 MPa (DN700-DN1200)
06    0.6 MPa  (DN700-DN1200)   Power Supply
10    1.0 MPa  (DN200-DN1200) [10] A Alternating current (85-265) VAC /(45-63)Hz
16    1.6 MPa  (DN15-DN600) D Direct current  (16-36) VDC
20    ANSI 150  (DN15-DN600) B   Battery  3.6 VDC
40    4.0 Mpa  (DN 3-DN150)   Output Signal & Input Signal
50    ANSI 300 (DN15-DN600) [11] 0   Basic configuration (Current output + pulse
  output + alarm output)
91    JIS 10K  (DN15-DN600)
92    JIS 20K  (DN15-DN600) 2   Basic configuration + RS232
93    Fixed-length model AMAG- I 4   Basic configuration + RS485
94    Pluggable Model AMAG- I-500 M   Basic configuration + MODBUS
95    Pluggable Model AMAG- I-900 H   Basic configuration + HART
99    Special pressure requirements(According to
   special order form)
P   Basic configuration + Profibus-DP
  Additional Function
[4] Lining Material [12] O No requirement J Relay output
1    Soft Neoprene (≤ DN1200) T Power-off recording F Enhancements
2    Hard Neoprene (≤ DN1200) Q Quantitative control S High-Frequency
3    PTFE (≤ DN1000) R Infrared remote control G GPRS communication
4    Polyurethane (≤ DN300) H Hourly accumulation L Ultralow temperatureconverter
5    PFA (≤ DN250)   Factory Inspection (Accuracy Level & Flow Point Number)
6    F46  (≤ DN250) [13] 1 0.5 level、3 point check 3 0.5 level、5 point check
7    Ceramics   (≤ DN250) 2 0.2 level、3 point check T Other requirement
[5] Electrode Material   Supplementary
1    Stainless steel  [316L]
[14]
0 No requirement
2    Hastelloy C  [Alloy-C22] 1 Stainless steel 304SS sensor(304SS flange)
3    Hastelloy B  [Alloy-B10] 2 Special requirements 1 (According to special order form)*
4    Titanium 3 Special requirements 2 (According to special order form) **
5    tantalum   Selection E.g.
6    Platinum/iridium Alloy  Flange type, DN150, 4 .0MPa, PTFE lining, Hastelloy alloy C electrode, body flange grounding, ambient temperature < 120℃, IP65 non-ex-proof,compact,AC power supply, basic configuration + RS485, no additional functional requirements, 0.5 level,3 point
 check, stainless steel sensor .Selection coding:RBEF-F15040320B1CA4011
7    Stainless steel coated tungsten carbide
8 Special conductive ceramics (Only for ceramic lining )
* E.g. :[14]=2,Marked 316SS flange, 304SS sensor shell.
** E.g. :[14]=3, Marked 316SS flange, 304SS sensor shell.

 

 



Applicants

RBEF-P Type Partial filled Electromagnetic Flow Meter(EMF) Applications:

  • Irrigation
  • Waste water
  • Rain water
  • Paper Industry
  • Public Drainage
  • Water Treatment
  • Etc..

 

 

 

Download