RBEFB-I Battery Powered Insertion Magnetic Flow Meter (Magmeters) is designed specifically for the water industry to meet the city's water supply to ensure the accurate calculation, the scene is widely used in places without power supply, such as urban water supply, sewage treatment, water conservancy and other industries.
The RBEFB-I Battery Powered Insertion Magmeters is ideal for use in process measurement and control, survey, leak detection, etc. applications such as leakage monitoring, and network analysis and in permanent locations where cost or space limitations preclude the use of conventional closed pipe meters. Battery Insertion Magmeters can be installed in any pipeline of internal diameter from 50mm (2in) to 8000mm (360in) through a small tapping.
RBEFB-I Battery- Powered Insertion Magnetic Flow Meter (Magmeter)
Battery Powered Insertion Magnetic Flow Meter (Battery Operation Insertion Emag meters)
The RBEF-I has two models: Fixeddepth model and Pluggable model.
1. Fixed depth Insertion Magnetic flow meter
Pipe Size |
Insertion Depth(D=pipe inner diameter) |
DN50~DN150 |
(1/8)*D |
DN200~DN600 |
(1/8)*D or (1/2)*D |
DN700~DN8000 |
(1/8)*D |
2. Pluggable Model Insertion Magnetic flow meter
Model |
Probe Length (mm) |
DN Size |
Insertion Depth (1/8)*D |
||
RBEF-I-B-500 |
500 |
DN50 ~ DN1600 |
RBEF-I-B-900 |
900 |
DN450 ~ DN4800 |
RBEF-I-B-1200 |
1200 |
DN1400 ~ DN7200 |
BEF-I-B-1500 |
1500 |
DN2000 ~ DN8000 |
|
||
Fig.3A Pluggable Model |
Fig.3B NPT G1.5” Connection |
The RBEF tube is made from stainless steel or titanium and its outer diameter is Ф27mm. The probe is made from stainless steel or titanium and PEEK and its outer diameter is Ф34mm. For the pluggable model, the connection between the probe and the pipeline is made through G screw or DN40 flange.
Specification
1. Suitable for pipeline size from DN50~DN8000mm;
2. Velocity range: 0.1~1m/s or 0.1~10m/s, span can be setup from 0.5m/s~10m/s.
3. Accuracy: velocity v≥1m/s, the accuracy is ±1.5%;
velocity 0.1m/s<v<1m/s, the accuracy is ±3%.
4. Liquid conductivity: >20μs/cm
5. Working pressure: 0.6MPa, 1.0MPa, 1.6MPa, 2.5MPa, 4.0MPa
6. Electrodes: SS316L,HC-22,HB3,Ti
7. Probe Material:SS304,SS316L, Ti (PEEK)
8. Maximum Liquid Temperature: PEEK 120℃
9. Enclosure IP: IP65、IP67,IP68 for remote type only
10. Maximum Cable Length: 100m (10m cable supplied if not specifically ordered)
11. Output Signal: 4~20mA, load: 0~500Ω;
Pulse: 1~5KHz, load: 250~1.2kΩ;
Communications: RS232C、RS485、MODBUS etc.
12. Other specifications refer to RBEFB Battery Magnetic Flow Converter manual.
RBEFB-I Insertion Type Magmeter Model Selection |
|
||||||||||||||||||||||||||||||||
RBEFB -I |
□□□ |
□□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
|
|
|||||||||||||||||
|
[1] |
[2] |
[3] |
[4] |
[5] |
[6] |
[7] |
[8] |
[9] |
[10] |
[11] |
[12] |
[13] |
[14] |
|
||||||||||||||||||
[1] |
Pipe Size(mm) |
|
[7] |
Protection Class |
|
||||||||||||||||||||||||||||
050 |
350 |
102 |
262 |
1 |
IP65 (Compact and remote type) |
|
|||||||||||||||||||||||||||
065 |
400 |
122 |
282 |
2 |
IP67 |
|
|||||||||||||||||||||||||||
080 |
450 |
142 |
302 |
3 |
IP68 (only Compact type) |
|
|||||||||||||||||||||||||||
100 |
500 |
162 |
402 |
|
|
||||||||||||||||||||||||||||
125 |
600 |
182 |
502 |
[8] |
Explosion Proofing |
|
|||||||||||||||||||||||||||
150 |
700 |
202 |
602 |
1 |
No |
|
|||||||||||||||||||||||||||
200 |
800 |
222 |
702 |
|
|
||||||||||||||||||||||||||||
300 |
900 |
242 |
802 |
[9] |
Configuration-Sensor/Transmitter |
|
|||||||||||||||||||||||||||
Sample:150 = DN150;122 = DN1200 |
C |
Compact (only DN50 --- DN1000) |
|
||||||||||||||||||||||||||||||
|
R |
Remote (Standard cable: 10m, other length, pls clarify.) |
|
||||||||||||||||||||||||||||||
[2] |
Flange Rating |
|
|
||||||||||||||||||||||||||||||
06 |
0.6 MPa (DN700 --- DN8000) |
[10] |
Power Supply |
|
|||||||||||||||||||||||||||||
10 |
1.0 MPa (DN200 --- DN1400) |
A |
85---265 VAC /45---63Hz |
|
|||||||||||||||||||||||||||||
16 |
1.6 MPa (DN50 --- DN600) |
D |
16---36 VDC |
|
|||||||||||||||||||||||||||||
20 |
ANSI 150 (DN15 --- DN600) |
B |
Battery Powered |
|
|||||||||||||||||||||||||||||
40 |
4.0 MPa (DN 50 --- DN150) |
|
|
||||||||||||||||||||||||||||||
50 |
ANSI 300 (DN50 --- DN600) |
[11] |
Output and Input |
|
|||||||||||||||||||||||||||||
J1 |
JIS 10K (DN50 --- DN300) |
0 |
RS485(battery) +Pulse(external power) |
|
|||||||||||||||||||||||||||||
J2 |
JIS 20K (DN50 --- DN300) |
2 |
GPRS |
|
|||||||||||||||||||||||||||||
AA |
Special |
4 |
GSM |
|
|||||||||||||||||||||||||||||
BB |
Pluggable with Remote Converter |
S |
Special |
|
|||||||||||||||||||||||||||||
2 |
On line Pluggable RBEFB-I -500 |
|
|
||||||||||||||||||||||||||||||
3 |
On line Pluggable RBEFB-I -900 |
[13] |
Factory Calibration |
|
|||||||||||||||||||||||||||||
4 |
On line Pluggable RBEFB-I -1200 |
1 |
3-point calibration,1.5% |
|
|||||||||||||||||||||||||||||
5 |
On line Pluggable RBEFB-I -1500 |
2 |
5-point calibration,1.5% |
|
|||||||||||||||||||||||||||||
|
T |
Other |
|
|
|||||||||||||||||||||||||||||
[4] |
Electrode material |
|
|
||||||||||||||||||||||||||||||
1 |
316L Stainless Steel [316L] |
[14] |
Probe Material(PEEK) |
|
|||||||||||||||||||||||||||||
2 |
Hastelloy C [Alloy-C22] |
1 |
SS304 |
|
|||||||||||||||||||||||||||||
3 |
Hastelloy B [Alloy-B10] |
2 |
SS316 |
|
|||||||||||||||||||||||||||||
4 |
titanium |
3 |
Ti |
|
|||||||||||||||||||||||||||||
5 |
tantalum |
Sample : DN150、4.0MPa、Fixed size type、316L electrode、The Probe Grounding、fluid type≤120℃、IP67、No-exproof 、Compact、Battery、Basic Configuration +RS485、no special function、3-point calibration、1.5%、no additional demand; proble material: SS304; Model:RBEF-I-I-15040110B21CA40101 |
|
||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||
[5] |
Grounding and Lining Protection |
|
|||||||||||||||||||||||||||||||
0 |
The Probe Grounding |
|
|||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||
[6]
|
Fluid Temperature |
|
|||||||||||||||||||||||||||||||
A |
≤80 ℃ |
|
|||||||||||||||||||||||||||||||
B |
≤120 ℃ |
|
|||||||||||||||||||||||||||||||
Battery Operated Insertion Emag.meter Applications:
Water & Wastewater industry
Pulp Paper & Power Generation industry
Irrigation System
Leakage Detection
HVAC Building Automation System
Smart Metering
Chemical Industry & Refinery Petrochemical industry
Liquid Flow meter Filling Machine