Inline (Flanged) type Ultrasonic Flow Meter uses transit-time ultrasonic technology in which the signal is transmitted and received alternately between 2 flow sensors and the “time of flight” determines the flow rate. Applications include both commercial and consumable water measurement. Long-term stability and a wide measurement range make it possible not only to measure water consumption, but also to monitor systems for water leakage.
Factory-calibrated for ultimate reliability. The RB Inline Ultrasonic Flow Meter is engineered for demanding industrial water and process liquid applications. By integrating the transducers directly into the flow tube, this meter eliminates the variables of pipe material and thickness, delivering superior or accuracy. With no moving parts to wear out and a full-bore design that causes zero pressure drop, it is the ideal long-term replacement for mechanical Woltman or turbine meters.
RBFM Series Inline transit time water flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method in which case the ultra sound transverses the pipe twice, or W-method in which case the ultra sound transverses the pipe four times, or in Z-method in which case the transducers are mounted on opposite sides of the pipe and the ultra sound transverses the pipe only once. The selection of mounting method depends on pipe and liquid characteristics. When the flow meter works, the two transducers transmits and receives ultrasonic signals amplified by multi beam which travels firstly downstream and then upstream (Figure 1). Because ultra sound travels faster downstream than upstream, there will be a difference of time of flight(△t). When the flow is still, the time difference(△t) is zero. Therefore, as long as we know the time of flight both downstream and upstream, we can work out the time difference, and then the flow velocity (V) and flow volume (Q) via the following formula.
V= K*D* △t
V: Liquid velocity
K: Constant
D: Distance between the two transducers
△t: Difference in time of flight
RBFM Flanged Type (Inline) Ultrasonic Flow Meters Features:
|
Pipe Size (mm) |
Pressure (MPa) |
Length (L) |
Flanged Outer D. |
D1 |
Screw D * quantity |
Seal Face |
Flanged Thickness |
|
|
D2 |
f |
|||||||
|
DN50 |
1.6 |
280 |
165 |
125 |
18×4 |
99 |
3 |
20 |
|
DN65 |
1.6 |
200 |
185 |
145 |
18×4 |
118 |
3 |
w20 |
|
DN80 |
1.6 |
225 |
200 |
160 |
18*4 |
132 |
3 |
22 |
|
DN100 |
1.6 |
220 |
220 |
180 |
18*8 |
156 |
3 |
22 |
|
DN125 |
1.6 |
275 |
250 |
210 |
18*8 |
184 |
3 |
22 |
|
DN150 |
1.6 |
300 |
285 |
240 |
22*8 |
211 |
3 |
24 |
|
DN200 |
1.6 |
350 |
340 |
295 |
22*12 |
266 |
3 |
24 |
|
DN250 |
1.6 |
450 |
405 |
355 |
26*12 |
319 |
3 |
26 |
|
DN300 |
1.6 |
500 |
460 |
410 |
26*12 |
370 |
4 |
28 |
|
DN350 |
1.0 |
550 |
505 |
460 |
26*16 |
428 |
4 |
30 |
|
DN400 |
1.0 |
600 |
565 |
515 |
26*16 |
482 |
4 |
30 |
|
DN450 |
1.0 |
700 |
615 |
565 |
26*20 |
532 |
4 |
30 |
|
DN500 |
1.0 |
800 |
670 |
620 |
26*20 |
585 |
4 |
32 |
|
DN600 |
1.0 |
1000 |
780 |
725 |
30*20 |
685 |
5 |
36 |
|
DN700 |
0.6 |
1100 |
860 |
810 |
26*24 |
772 |
4 |
40 |
|
DN800 |
0.6 |
1200 |
975 |
920 |
30*24 |
878 |
4 |
44 |
|
DN900 |
0.6 |
1300 |
1075 |
1020 |
30*24 |
9781 |
4 |
48 |
|
DN1000 |
0.6 |
1400 |
1175 |
1120 |
30*28 |
1078 |
4 |
52 |
RBBF Flanged Type (Inline) Ultrasonic Flow Meters Model Selection:
|
RBFM |
X |
|
X |
X |
DNxx |
X |
X |
|
X |
X |
X |
|
|
|
Instrument Type |
|
||||||||||
|
F |
Ultrasonic Flow meter |
|||||||||||
|
H |
Ultrasonic Heat meter |
|||||||||||
|
|
Power supply |
|||||||||||
|
A |
85 to 265VAC |
|||||||||||
|
D |
24VDC |
|||||||||||
|
B |
Battery |
|||||||||||
|
|
Flow/Heat meter Type |
|||||||||||
|
F |
Flanged type |
|||||||||||
|
|
|
|
|
Transducer Type |
||||||||
|
50 |
||||||||||||
|
|
65 |
|||||||||||
|
80 |
||||||||||||
|
100 |
||||||||||||
|
125 |
||||||||||||
|
150 |
||||||||||||
|
200 |
||||||||||||
|
250 |
||||||||||||
|
300 |
||||||||||||
|
350 |
||||||||||||
|
400 |
||||||||||||
|
450 |
||||||||||||
|
500 |
||||||||||||
|
600 |
||||||||||||
|
700 |
||||||||||||
|
800 |
||||||||||||
|
900 |
||||||||||||
|
1000 |
||||||||||||
|
|
Pt100 |
Temperature sensor |
||||||||||
|
|
DNxx |
Pipe size |
|
|||||||||
|
|
|
Pipe material |
|
|||||||||
|
|
C |
Carbon Steel |
||||||||||
|
SS |
Stainless Steel |
|||||||||||
|
X |
Others, clarify |
|||||||||||
|
|
X |
Pressure(MPa) |
||||||||||
|
|
Output |
|||||||||||
|
N |
NO |
|||||||||||
|
A |
4-20mA |
|||||||||||
|
P |
Pulse |
|||||||||||
|
R |
Relay |
|||||||||||
|
2 |
RS232 |
|||||||||||
|
4 |
RS485 |
|||||||||||
|
5 |
Datalogger |
|||||||||||
|
|
Input |
|
||||||||||
|
N |
NO |
|||||||||||
|
1 |
1*4-20mA |
|||||||||||
|
2 |
2*4-20mA |
|||||||||||
|
3 |
3*4-20mA |
|||||||||||
|
|
Cable length |
|||||||||||
|
X |
meter |
|||||||||||
RBFM Flanged Type (Inline) Ultrasonic Flow Meters Applications