Ceramic Magnetic flow meter

The RBEF Ceramic magnetic flow meters have ceramic liners in place of the typical elastomer liners commonly used in magnetic flow meters. The ceramic measuring tubes feature an outstanding combination of material properties including surface hardness and quality, mechanical stability and resistance to corrosion and temperature change. Benefits for the operator include ultimate accuracy and long-term stability as well as vacuum resistance and diffusion resistance. The versatile profile combined with the high accuracy, these flow meters are used in all sectors of industry.

 

 

 

 

Description

  • Features
  • Specification
  • Model Selection
  • Applicants
  • Download
Features

RBEF Ceramic magnetic flow meters Features

  • Tube with high-tech ceramic material, fulfilling fully vacuum-resistant.
  •  Special tube design with conical parts, optimizing the flow profile.
  •  The smooth and pore free ceramic tube construction does not leak.
  •  Insensitive for temperature shocks, exceptional long-term stability and accuracy.
  •  Highly aggressive and abrasive fluids for slurry applications.
  •  Stable measurement in noisy applications.
  •  Improved safety with absolute leak tight design making it highly suitable for hygienic applications.
  •  Excellent chemical and abrasion resistance, fulfilling requirements of the chemical industry.
  •  Diameter range of DN15 up to DN200, DN15...100: PN 40, DN150...200: PN16 or PN 100.
Specification

RBEF Emag.meters Specifications

Sizes

Flanged (Metric)

DN15…DN3000

Flanged (US)

1/2”… 118”

Wafer Design

DN15…DN100

Nominal Pressure

GB,JIS and DIN Flange

0.6 MPa, 1.0 MPa, 1.6 MPa, 4.0 MPa

ANSI Flange

Class 150, Class 300

Wafer Design

1.6 MPa, 4.0 MPa

For additional pressure requirements, please contact manufacturer

Accuracy (pulse output)

Standard

±0.5% (0.6m/sec to 12 m/sec)

Optional

±0.2% (1.0m/sec to 12 m/sec)

Measurement Resolution

±1mm/sec

Max Flow Tube Velocity

SI:

49 ft/s

US:

12 m/s

Ambient Temperature

-25…+55°C   /   -13…+131°F

Relative Humidity

5%…90%

Conductivity

≥5 μS/cm

Transmitter Mounting Availability

Compact type 

Sizes: DN15…DN1000

1/2”…40”

Remote type 

Sizes: DN15…DN3000

1/2”… 118”

Note 1: Cable between flow tube and remote transmitter is type SMFE100

Note 2: Remote unit supplied with 10m cable as standard

Note 3: Max cable length is 200m (650ft)

 

Material

SI

US

Liner Material Options

Neoprene (std)

DN15…DN3000

1/2”…56”

PTFE

DN15…DN1000

1/2”…40”

Polyurethane

DN15…DN300

1/2”…12”

PFA

DN15…DN250

1/2”…10”

PFA with optional wire reinforcement

DN80…DN250

3”…10”

Tefzel

DN15…DN250

1/2”…10”

Tefzel with optional wire reinforcement

DN80…DN250

3”…10”

 

Ceramic liner and electrodes

DN15…DN200

1/2”…8”

Electrode Material Options

316L stainless steel (std)

DN15…DN3000

1/2”…56”

Hastelloy – C22

DN15…DN1000

1/2”…40”

Hastelloy – B10

DN15…DN1000

1/2”…40”

Titanium

DN15…DN250

1/2”…10”

Tantalum

DN15…DN250

1/2”…10”

Platinum/iridium Alloy

DN15…DN250

1/2”…10”

316L with tungsten carbide coating

DN15…DN600

1/2”…24”

Grounding Options

Flange Grounding

DN15…DN3000

1/2”…56”

Grounding Ring

DN15…DN250

1/2”…10”

Electrode Grounding

DN50…DN3000

2”…56”

Inlet protection ring

DN50…DN300

2”…12”

 

Type

Liner

Standard

Optional

Max Process Temperature Limits

Compact

Neoprene

80°C / 176°F

120°C / 248°F

PTFE

80°C / 176°F

120°C / 248°F

Polyurethane

80°C / 176°F

-

PFA

80°C / 176°F

120°C / 248°F

Tefzel

80°C / 176°F

-

Remote

Neoprene

80°C / 176°F

120°C / 248°F

PTFE

80°C / 176°F

120°C / 248°F

180°C / 356°F

Polyurethane

80°C / 176°F

-

PFA

80°C / 176°F

120°C / 248°F

Tefzel

80°C / 176°F

-

Environmental Protection Class

Compact

IP 65

IP67

Remote

IP 65

IP 68

Power Supply Options

85…265VAC / 45…63Hz, 20VA

16…36VDC, 16VA

Display

2 or 3 line backlit LCD

Configuration Access

Front panel keypad

Hand held infrared remote control (optional)

Output Signals

Active analog current output

Max load resistance 0…1.5kΩ for 0…10mA

0…750Ω for 4…20mA

Accuracy = same as pulse output ±0.1% of rate

Option: HART Protocol

Passive analog current output 

Requires 24Vdc external supply to operate

Accuracy = same as pulse output ±0.1% of rate

Pulse / frequency and alarm outputs

Optically isolated open collector output powered either internally or externally

  Int. power:  28VDC with 1.2kΩ pull-up resistor

  Ext. power:  ≤36VDC, max current 250mA

Digital Communications

RS485 Modbus

GPRS (superimposed on current output)

All interfaces have built in lightning protection

Electrical isolation

Isolation between all I/O and input power no less than 500V

Isolation between all I/O and ground no less than 500V

Isolation between flow tube and transmitter outputs no less than 500V

Standard

JB/T 9248-1999 Electromagnetic Flow meter

(1) Line size selection will be inches for ANSI Class 150/300 rating selection, DIN size for all other ratings

(2) Order longer cable length separately

(3) Ceramic liner and electrodes is with wafer type only

Model Selection

RBEF Emag.meters Model Selection

RBEF-

DN

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

 

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

13

 

14

15

 

1 Nominal Diameter(mm)/ [inches] (1)

0015 [½”]

0100 [4”]

0450 [18”]

1400 [56”]

0020 [¾”]

0125 [5”]

0500 [20”]

1600

0025 [1”]

0150 [6”]

0600 [24”]

1800

0032 [1¼]

0200 [8”]

0700 [28”]

2000

0040 [1½]

0250 [10”]

0800 [32”]

2200

0050 [2”]

0300 [12”]

0900 [36”]

2400

0065 [2½]

0350 [14”]

1000 [40”]

2600

0080 [3”]

0400 [16”]

1200 [48”]

3000

 

 

 

 

 

2 Flange Rating (1)

02

0.25 MPa

1600 … 3000

06

0.6 MPa 

700 … 3000

10

1.0 MPa 

200 … 1400

16

1.6 MPa 

15 … 600

20

ANSI Class 150

15 …1400

40

4.0 MPa 

15 … 150

50

ANSI Class 300

15 … 1400

AA

Special

 

 

 

 

 

3 Electrode Material

1

316L Stainless Steel

3

Hastelloy C-22

4

Hastelloy B-10

5

Titanium

6

Tantalum

7

Platinum / Iridium Alloy

8

Tungsten Coated Stainless Steel

9

ceramic

 

 

 

4 Lining Material

1

Neoprene (Hard rubber)

≤ 3000

2

PTFE

≤ 1000

3

Polyurethane

≤ 300

4

PFA

≤ 250

5

Tefzel

≤ 250

6

PFA with Wire Net

80 … 250

7

Tefzel with Wire Net

80 … 250 

8

Ceramic

15 … 200

 

 

 

 

5 Grounding and Lining Protection

0

Flange ground

15 … 3000

1

Earth ring

15 … 250

 2

Ground electrode

50 … 3000

3

Inlet protection ring

50 … 3000

 

 

 

 

6 Max. Process Temperature

A

80°C

All Linings

B

120°C

Neoprene / PTFE / PFA / Tefzel

C

180°C

PTFE only

 

 

 

 

 

 

 

 

 

7 Environmental Protection Class

1

IP65

2

IP67 (Compact Type Only)

3

IP68 (Remote Type Only)

 

 

 

8 Explosion Proofing

1

None

2

Ex DE IIC T6

 

 

 

9 Configuration – sensor/transmitter 

1

Compact (15 … 1000)

2

Remote (with 10m cable)(2)

3

Wafer

 

 

 

10 Power Supply

A

AC: 85 … 265 VAC / 45 … 63Hz

D

DC: 18 … 36 VDC

 

 

 

11 Display and Programming

2

2 line LCD display + keypad programming

3

3 line LCD display + keypad programming

 

 

 

12 Output and Input

0

Basic Configuration (current, pulse and contact outputs)

2

Basic Configuration + RS485

3

Basic Configuration + GPRS

4

Basic Configuration + MODBUS

 

 

 

 

13 Calibration Specification

1

3 point, 0.5% accuracy

2

3 point, 0.25% accuracy

3

Special

 

 

 

14 Flow Tube Configuration

1

Flange Type

15 … 3000

D

DIN

 

A

ANSI

 

O

Others(pls clarify)

 

2

Flange type with removable electrodes

15 … 3000

3

Flange material

 

C

Carbon Steel

 

S

304 Stainless Steel

 

 

 

 

 

15 Special Function

0

No

R

IR Remote

T

Power off timer

H

Cumulative hours

Q

Quantitative control

J

Relay Output

Remark:

(1) Line size selection will be inches for ANSI Class 150/300 rating selection, DIN size for all other ratings

(2) Order longer cable length separately

(3) Ceramic liner and electrodes is with wafer type only

Applicants

RBEF Ceramic magnetic flow meters Applications:

  • Chemical Processing Industry
  •  Paper & Pulp
  •  (Waste) water
  •  Minerals & Mining
  •  Food & beverage
  •  Machinery
  •  Pharmaceuticals
Download

product search