RBFM-K Compact Clamp-on UltrasonicFlow and Heat Meter specification:
|
Specifications |
Data |
|
Pipe material |
Metal /PVC, PP or PVDF rigid plastic pipe |
|
Liquid type |
Water/other liquid (Single liquid medium without solid particles or impurities) |
|
Temperature range |
0-75℃ (No freezing on the surface) |
|
Low velocity cut off value (Default by factory) |
0.1m/s |
|
Display |
256*128, LCD |
|
Response time |
0.5~60s |
|
Accuracy |
±2%, (±1% after calibration) |
|
Data Storage period |
300ms |
|
Memory for data backup |
EEPROM (Data storage: over 10 years, data read/write frequency: over 1 million times) |
|
Power and I/O connection |
M12 type aviation plug |
|
Output |
4-20mA |
|
Communication |
Modbus RS485 |
|
(Options for output) |
OCT (pulse output)/ One relay alarm (please contact the factory) |
|
Power supply |
10-24V VDC |
|
Electric power |
< 3W |
|
Protective circuit |
Power reverse connection protection, Power surge protection, Output short circuit protection, Output surge protection |
|
Enclosure protection class |
IP65 |
|
Environment temperature |
-10 to 60°C (No freezing) |
|
Relative humidity |
35 to 85% RH (No condensation) |
|
Vibration resistance |
10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each XYZ axis |
|
Impact resistant |
100 m/s2 16ms pulse, 1000 times each for X, Y and Z axes |
|
Main material |
Aluminum, Industrial Plastics |
RBFM-K Compact Clamp-on UltrasonicFlow and Heat Meter Model Selection:
| RBFM-K Compact Flow/Heat Meter Model Selection | ||||||||
| RBFM-K- | Pipe size | |||||||
| 15 | DN15 | |||||||
| 20 | DN20 | |||||||
| 25 | DN25 | |||||||
| 32 | DN32 | |||||||
| 40 | DN40 | |||||||
| 50 | DN50 | |||||||
| 65 | DN65 | |||||||
| Fluid type: | ||||||||
| 1 | water | |||||||
| 2 | Others, pls clarify it | |||||||
| Flow/Heat | ||||||||
| F | Flow | |||||||
| H | Flow/Heat with Pt1000 temp. sensor | |||||||
| Ultrasonic Sensor cable | ||||||||
| S | Standard length-2m | |||||||
| X | Xm cable | |||||||
| Type of Transducer | ||||||||
| T1 | 0-65℃ | |||||||
| T2 | 0-115℃ | |||||||
| Output(only choose 2 out of 4) | ||||||||
| A | 4-20mA | |||||||
| M | Modbus(RS485) | |||||||
| O | OCT(Frequency) | |||||||
| R | 1pc Relay | |||||||
| Temperature sensor length | ||||||||
| N | No temp. sensor | |||||||
| 9 | Standard length-9m | |||||||
| 15 | Extend cable length 15m | |||||||
| 25 | Extend cable length 25m | |||||||
RBFM-K Compact Clamp-on Micro UltrasonicFlow and Heat Meter Application:
Magmeters
Ultrassonic Flow Meter
Coriolis, Thermal Mass Flow Meter
Other Process Instrument