The measurement technology for ultra-low conductivity media breaks through the requirements of electromagnetic flowmeters for the conductivity of media and has been successfully applied to media with a conductivity as low as 1μS/cm.
RBHEF-LC Low Conductivity Electromagnetic Flowmeter is specially designed for measuring the flow rate of low-conductivity liquids (such as pure water, deionized water, organic solvents, etc.), breaking through the high requirements of traditional electromagnetic flowmeters for dielectric conductivity.
Using high-frequency excitation technology and intelligent signal processing algorithms to ensure high-precision measurement under extremely low conductivity conditions as low as 1 μS/cm, it is widely used in high-clean industries such as semiconductors, pharmaceuticals, food and beverages.
RBHEF-LC series Ultra-Low Conductivity Magnetic Inductive Flow Meter Features:
Ultra-Low Conductivity Compatibility
RBHEF-LC series Ultra-Low Conductivity Magnetic Inductive Flow Meter Specification:
Measuring Pipe Size |
DN10-DN200 |
Connection |
Flange |
Liner Material |
FEP, PU |
Electrode Material |
316L、Hc |
Structure Type |
Compact, Remote Type |
Accuracy |
0.2%、0.3%、0.5% |
Output Signal |
4-20mA, Pulse |
Communication |
HART, MODBUS, BACNET |
Temperature |
AT~ 110 ℃ (AT refers to the ambient temperature) |
Protection Class |
Transmitter: IP65 |
|
Flow Sensor: 65, 67,68 |
Display: |
Instantaneous/Total Flow, Velocity, Flow Percentage, Bidirectional, etc. |
Power supply |
24VDC、220VAC |
Ex-proof |
Exia/de IICT3~T6 Ga/Gb ExibD21Da21IP65T135 |
Pressure Class |
PN10-40 |
Connection Type |
Flange, Wafer, Triclamp |
RBHEF-LC series Ultra-Low Conductivity Magnetic Inductive Flow Meter Model Selection :
RBHEF-LC Low Conductivity Electromagnetic Flowmeter
Model Selection |
|||||||||||||
|
Pipe Size |
||||||||||||
10 |
DN10 |
||||||||||||
15 |
DN15 |
||||||||||||
... |
... |
||||||||||||
200 |
DN200 |
||||||||||||
|
Power |
||||||||||||
D |
24VDC |
||||||||||||
A |
240VAC |
||||||||||||
|
Ex-proof |
||||||||||||
N |
No |
||||||||||||
T6 |
Ex ia/db eb ΙΙC T3··· T6 Ga Ex tb ⅢC T200℃ Db |
||||||||||||
|
Electrode |
||||||||||||
S |
SS316L |
||||||||||||
Hc |
Hc |
||||||||||||
X |
Special |
||||||||||||
|
Liner* |
||||||||||||
N |
Neoprene |
||||||||||||
F |
FEP |
||||||||||||
1 |
PTFE |
||||||||||||
2 |
PU |
||||||||||||
3 |
PFA |
||||||||||||
|
Output |
||||||||||||
A |
4-20mA+Pulse |
||||||||||||
H |
4-20mA+Pulse +Hart |
||||||||||||
M |
Modbus RTU |
||||||||||||
|
Connection type |
||||||||||||
F |
Flanges (DN10 to DN200) |
||||||||||||
T |
Triclamp (DN10 to DN125) |
||||||||||||
S |
Thread (DN10 to DN40) |
||||||||||||
X |
Wafer (DN50 to DN200) |
||||||||||||
|
Medium temperature range (AT refers to the ambient temperature) |
||||||||||||
0 |
AT^80℃ |
||||||||||||
S |
Special |
||||||||||||
|
Grounding Type |
||||||||||||
1 |
SS316 Grounding |
||||||||||||
2 |
SS316L Grounding Ring |
||||||||||||
3 |
HC Grounding |
||||||||||||
4 |
HC Grounding Ring |
||||||||||||
|
IP Class |
||||||||||||
5 |
IP65 |
||||||||||||
7 |
IP67 |
||||||||||||
8 |
IP68(Remote type only |
||||||||||||
|
Shell type |
||||||||||||
C |
Compact |
||||||||||||
Rx |
Remote type with Xm cable |
||||||||||||
|
|
|
|
|
|
|
|
Other Function |
|||||
0 |
/ |
||||||||||||
1 |
Batching Control |
||||||||||||
2 |
Reverse Flow Alarm |
||||||||||||
3 |
Upper and Lower Limit Alarms |
Remark:
1. Liner* select: refer to the applicable pipe diameter range in the attached table;
The RBHEF-LC series low - conductivity electromagnetic flowmeter Applications :
The RBEF8C series low - conductivity electromagnetic flowmeter, suitable for liquids with conductivity > 1 μS/cm (e.g., pure water, 98% alcohol), has applications in multiple industries.
1. Electronic Manufacturing
- Chip production, Deionized water
- In chip manufacturing, deionized water for cleaning and cooling needs precise flow control. The RBEF8C series accurately measures its flow, ensuring high chip yields.
2. Chemical Industry
- Chemical reactions, Organic solvents
- During chemical synthesis, organic solvents like 98% alcohol require accurate flow measurement for reaction stability. This flowmeter functions well in complex chemical settings to measure their flow.
3. Pharmaceutical Industry
-Drug production, Quality assurance - In pharmaceutical processes, pure and deionized water are used. Precise flow measurement by the RBEF8C series guarantees consistent drug quality. Its corrosion - resistant design suits pharmaceutical media.
4. Food & Beverage Industry
- Beverage formulation, Alcohol blending - For beverage production, especially in blending water and alcohol (e.g., in baijiu making), the flowmeter precisely controls ingredient flow, maintaining product quality and taste.
5. Power Industry
- Power plant operation, Boiler feedwater - Power plants use the RBEF8C series to measure pure and demineralized water flow for boiler feedwater and cooling systems, ensuring efficient power generation.
6. Water Treatment
- Urban water supply, Sewage treatment - In urban water supply, it measures treated water flow for distribution. In sewage treatment, it monitors the discharge of treated water.
7. Research Laboratories
- Lab experiments, High - precision measurement - In scientific labs, when dealing with low - conductivity liquids in experiments, the RBEF8C series provides the high - precision flow measurement required for accurate results.
Magmeters
Ultrassonic Flow Meter
Coriolis, Thermal Mass Flow Meter
Other Process Instrument