Fixed Clamp-on type Ultrasonic Flow Meter

The RBBF Clamp-on Ultrasonic Flow Meter is a fixed-mount, low cost transit-time ultrasonic flow meter with clamp-on transducers for non-invasive liquid flow rate measurement. Our microprocessor-based, user friendly field programmable creates no interruption of the process flow and has low installation costs.

This versatile series of flow meters is available in a variety of configurations. Available transducer types include clamp-on, in-line, and insertion. Wall-mount, panel-mount, pipe-mounted and compact din-rail mounted display types are also offered. Additional available features include pulse, 0-20mA & 4-20mA outputs, RS-232 communication, user-selectable engineering units, and a data logger function.

Description

  • Principle
  • Features
  • Specification
  • Model Selection
  • Applicants
  • Download
Principle

Measuring principle of Transit-time Ultrasonic Flowmeters

RBFM Series Clamp-on  transit time flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method in which case the ultra sound transverses the pipe twice, or W-method in which case the ultra sound transverses the pipe four times, or in Z-method in which case the transducers are mounted on opposite sides of the pipe and the ultra sound transverses the pipe only once. The selection of mounting method depends on pipe and liquid characteristics. When the flow meter works, the two transducers transmits and receives ultrasonic signals amplified by multi beam which travels firstly downstream and then upstream (Figure 1). Because  ultra sound travels faster downstream than upstream, there will be a difference of time of flight(△t). When the flow is still, the time difference(△t) is zero. Therefore, as long as we know the time of flight both downstream and upstream, we can work out the time difference, and then the flow velocity (V) and flow volume (Q) via the following formula.

 V= K*D*                

V: Liquid velocity

K: Constant

D: Distance between the two transducers

△t: Difference in time of flight

 

 

Features

RBBF Fixed  Clamp-on Type Ultrasonic Flow Meter Features:

  • Wide range velocities of ±0.1~ ± 12m/s (0.03 ~ ± 105 feet/sec.)
  • High accuracy of ± 1% of reading.
  • Transducers for pipe sizes ranging from13 to 6000 mm (½" to 240").
  • Fast response time - less than 1 second.
  • 2 line LCD display with flow rate, totalizer & signal condition.
  • Stores up 64 Day/months totalzier daily value.
  • Batch control function
  • Transducers for pipe sizes ranging from13 to 6000 mm (½" to 240").
  • 0-20mA & 4-20mA outputs, RS-232 communication, user-selectable engineering units, and a data logger function
  • Clamp-on transducers feature integral magnet for installation on metal pipe without use of a mounting belt
  • Data logger function includes date, totalizer, & signal condition diagnostic

 


Specification

RBBF Fixed Clamp-on Type Ultrasonic Flow Meter Features:

 

Transducer 

Standard Type   

S type

Pipe size

(15 mm ~ 100 mm) ½" ~ 4"

SN

SH

-30~160℃

Size(mm)

SN

45×25×28

M Type

Pipe size

50 mm ~ 700 mm (2" ~ 28" )

Temp.

MN

-30~160℃

Size(mm)

MN:

64×35×32

L Type

Pipe size

300~ 6000(12" ~ 240" )

Temp.

LN

-30~160℃

Size(mm)

LN

97×54×53

 

Insertion Type

Pipe size

80~6000mm

Temp.

RCN

-40 ~ 160℃

RCL(Extended)

-40 ~ 160℃

 

Temp. Sensor 

 

Pt100 3 wires 

 

Pt100 3 wires(only for small pipes)

Fluid

Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single uniform liquid

Flow Direction

Bi-directional measuring, net flow/heat measuring

Accuracy

± 1% ~ ± 2% of reading (1.5 ~ 100 feet/sec.)

Repeatability

± 0.2% of reading

Flow rate range

0.01 ~ ± 12 m/s

Response Time

Less than 1 second

Keypad

16 Key with tactile action

Pipe Material

Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed

Liner Material

Tar Epoxy, Rubber, Mortar, Polypropylene, Polystryal, Polystyrenes, Polyester, Ebonite, Polyethylene, Teflon, etc.

Mounting

wall mounting, local

Display

2 Line LCD with backlight; 5 digits with decimal point for flow rate, 8 digits for Forward, Reverse & Net totalized values

Output

Analog

4-20mA or 0-20mA current output. Impedance 0∼1kW. Accuracy 0.1%.

Relay output

Over 20 source signal (no signal, reverse flow etc.)

Pulse Output

Frequency signal :1~9999 Hz

Input

Three analogue input

Three-wire PT100 resistor input (optional)

Other functions

Automatically record the totaliser data of the last 64 days / 64 months / 5 years;

The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation

The instrument working status of the last 64 days

Communication

RS-232/RS485

Alarm

High/Low with buzzer

Protection

Transmitter

IP 65

Sensor

IP67/IP68 (optional)

Straight pipe section

In the upstream it must be beyond 10D, in the downstream it must be beyond 5D, in the upstream the length must be beyond 30D from the access of the pump. (D stands for pipe diameter)

Cable Length

Twisted Pair Line, standard length of 10m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement. RS-485 interface, transmission distance up to 1000m

Power Supply

Remote Type

90 ~ 260VAC 50/60 Hz; 9-28VDC

Compact Type

9-28VDC

Power Consumption

Less than 2W

Data Storage

Operation parameters and tantalization data are stored in EEPROM for more than 10 years

Engineer Unit

M3, Liter, US gallon, Imperial gallon, Million gallons, Cubic feet, US Barrels, Imperial barrels, Oil barrels

Time Units

Second, Minute, Hour, Day

Protocols

MODBUS, M-BUS, Fuji extended protocol and other factory protocol

Humidity

Main Unit: 85% RH

Remarks:  With a high strength carrying case suitable for normal and harsh environment

Model Selection

RBFM Ultrasonic Flow/Heat Meter Model Selection

RBFM 

X

 

X

X

DNxx

X

X

 

X

X

X

 

 

Instrument Type

 

 

F

Ultrasonic Flowmeter

H

Ultrasonic Heat meter

 

Power supply

A

220VAC

D

24VDC

B

Battery

 

Flow/Heat meter Type

 

F

Fixed type

H

Handheld type

F

Flanged type

B

Battery type

 

  

  

  

Transducer Type

 

 

SN

S type(pipe size: 15-100mm, temp.: -30 to 90℃)

SH

S type(pipe size: 15-100mm, temp.: -40 to 160℃)

SPMN

S type with mounting frame only for Handheld (pipe size: 15-100mm, temp.: -40 to 90℃)

SPMH

S type with mounting frame only for Handheld(pipe size: 15-100mm, temp.: -40 to 160℃)

MN

M Type(pipe size: 50-700mm, temp.: -30 to 90℃))

MH

M Type(pipe size: 50-700mm, temp.: -40 to 160℃))

MPMN

M type with mounting frame only for  Handheld (pipe size: 50-300mm, temp.: -40 to 90℃)

MPMH

M type with mounting frame only for Handheld (pipe size: 50-300mm, temp.: -40 to 160℃)

RB-1

extended the mounting frame, for pipe:DN300-700mm, temp.: -40 to 90℃

RBH

extended the mounting frame, for pipe:DN300-700mm, temp.: -40 to 90℃

LN

L type(pipe size: 300-6000mm, temp.: -30 to 90℃)

LH

L type(pipe size: 300-6000mm, temp.: -40 to 160℃)

I

Insertion Type

IE

Extended type

F

Flanged type

 

Pt100

Temperature sensor

 

 

DNxx

Pipe size

  

 

 

Pipe material

  

 

C

Carbon Steel

SS

Stainless Steel

CI

cast iron

F

Fibreglass

P

PVC

C

cement pipe

X

Others,  clarify

 

X

Pressure(MPa)

 

 

Output

 

N

NO

A

4-20mA

P

Pulse

R

Relay

2

RS232

4

RS485

5

Datalogger

 

Input

 

N

NO

1

1*4-20mA

2

2*4-20mA

3

3*4-20mA

 

Cable length

X

meter

Applicants

RBBF Fixed Clamp-on Type Ultrasonic Flow Meter can be applied to a wide range of pipe flow measurements.

Applicable liquids include pure liquids as well as liquid with small quantity of tiny particles.

Examples are:

Water (hot water, chilled water, city water, sea water, waste water, etc.);

Sewage with small particle content;

Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);

Chemicals (alcohol, acids, etc.);

Plant effluent;

Beverage, liquid food;

Ultra-pure liquids;

Solvents and other liquids 

Download