The RBEF-I Insertion Electromagnetic flow meter(Emag meters) can be installed in any pipeline of internal diameter from 50mm (2in) to 8000mm (360in) through a small tapping.
The RBEF flow meters are ideal for use in process measurement and control, survey, leak detection, etc. applications such as leakage monitoring, and network analysis and in permanent locations where cost or space limitations preclude the use of conventional closed pipe meters.
RBEF-I Insertion Electromagnetic flow meter types:
Principle of Operation
Faraday’s law of electromagnetic induction states that an inductive voltage is generated when a conductor moves through a magnetic field. This principle is used as the basis of flow measurement in the RBEF-I electromagnetic flow meter. In the electromagnetic flow meter, the flowing fluid corresponds to the moving conductor as described in Faraday’s law.
UE ∞ B * D * v
The induced voltage UE is directly proportional to magnetic field intensity (B), electrode spacing (D) and average fluid velocity (v). Since magnetic field intensity (B) and the electrode spacing (D) are constant values, induced voltage UE is therefore directly proportional to the average flow velocity (v).
Q = (∏ * D2) / 4 * v therefore UE ∞ Q
The equation for calculating volumetric flow rate (Q) shows that the induced voltage (UE) is linear and directly proportional to the average velocity (v). In the flow meter transmitter, the induced voltage (UE) from the electrodes is used to calculate volumetric flow rate (Q) based upon the pipe’s internal diameter.
UE = Induced voltage
B = Magnetic field strength
Fig. 1 The Principle of Insertion Flowmeter
D = Electrode spacing
V = Fluid velocity
Q = Instantaneous volumetric flow rate
The RBEF-I Insertion Magnetic flow meter(Mag meters)consists of insertion probe and converter.
Insertion Electromagnetic flow meter(Emag meters)
The RBEF-I has two models: Fixeddepth model and Pluggable model.
1. Fixed depth Insertion Magnetic flow meter
Pipe Size |
Insertion Depth(D=pipe inner diameter) |
DN50~DN150 |
(1/8)*D |
DN200~DN600 |
(1/8)*D or (1/2)*D |
DN700~DN8000 |
(1/8)*D |
2. Pluggable Model Insertion Magnetic flow meter
Model |
Probe Length (mm) |
DN Size |
Insertion Depth (1/8)*D |
||
RBEF-I-B-500 |
500 |
DN50 ~ DN1600 |
RBEF-I-B-900 |
900 |
DN450 ~ DN4800 |
RBEF-I-B-1200 |
1200 |
DN1400 ~ DN7200 |
BEF-I-B-1500 |
1500 |
DN2000 ~ DN8000 |
|
||
Fig.3A Pluggable Model |
Fig.3B NPT G1.5” Connection |
The RBEF tube is made from stainless steel or titanium and its outer diameter is Ф27mm. The probe is made from stainless steel or titanium and PEEK and its outer diameter is Ф34mm. For the pluggable model, the connection between the probe and the pipeline is made through G screw or DN40 flange.
Specification
1. Suitable for pipeline size from DN50~DN8000mm;
Probe Insertion Depth Table
Pipeline Size |
Probe Insertion Depth(D=Pipeline Inner Diameter) |
DN50~DN150 |
(1/8)*D |
DN200~DN600 |
(1/8)*D or (1/2)*D |
DN700~DN8000 |
(1/8)*D |
2. Velocity range: 0.1~1m/s or 0.1~10m/s, span can be setup from 0.5m/s~10m/s.
3. Accuracy: velocity v≥1m/s, the accuracy is ±1.5%;
velocity 0.1m/s<v<1m/s, the accuracy is ±3%.
4. Liquid conductivity: >20μs/cm
5. Working pressure: 0.6MPa, 1.0MPa, 1.6MPa, 2.5MPa, 4.0MPa
6. Electrodes: SS316L,HC-22,HB3,Ti
7. Probe Material:SS304,SS316L, Ti (PEEK)
8. Maximum Liquid Temperature: PEEK 120℃
9. Enclosure IP: IP65、IP67,IP68 for remote type only
10. Maximum Cable Length: 100m (10m cable supplied if not specifically ordered)
11. Output Signal: 4~20mA, load: 0~500Ω;
Pulse: 1~5KHz, load: 250~1.2kΩ;
Communications: RS232C、RS485、MODBUS etc.
12. Other specifications refer to RBMAG converter manual.
The RBEF Insertion type Magnetic flow meter
RBEF-I |
□□□ |
□□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
□ |
||||||||||||||||||||
|
[1] |
[2] |
[3] |
[4] |
[5] |
[6] |
[7] |
[8] |
[9] |
[10] |
[11] |
[12] |
[13] |
[14] |
[15] |
||||||||||||||||||||
[1] |
Pipe Size(mm) |
|
[7] |
Protection Class |
|||||||||||||||||||||||||||||||
050 |
350 |
102 |
262 |
1 |
IP65 |
||||||||||||||||||||||||||||||
065 |
400 |
122 |
282 |
2 |
IP67 (Only Compact) |
||||||||||||||||||||||||||||||
080 |
450 |
142 |
302 |
3 |
IP68 (Only remote type, specify the cable length) |
||||||||||||||||||||||||||||||
100 |
500 |
162 |
402 |
|
|||||||||||||||||||||||||||||||
125 |
600 |
182 |
502 |
[8] |
Explosion Proofing |
||||||||||||||||||||||||||||||
150 |
700 |
202 |
602 |
1 |
No |
||||||||||||||||||||||||||||||
200 |
800 |
222 |
702 |
|
|||||||||||||||||||||||||||||||
300 |
900 |
242 |
802 |
[9] |
Configuration-Sensor/Transmitter |
||||||||||||||||||||||||||||||
Sample:150 = DN150;122 = DN1200 |
C |
Compact (only DN50 --- DN1000) |
|||||||||||||||||||||||||||||||||
|
R |
Remote (Standard cable: 10m, other length, pls clarify.) |
|||||||||||||||||||||||||||||||||
[2] |
Flange Rating |
|
|||||||||||||||||||||||||||||||||
06 |
0.6 MPa (DN700 --- DN8000) |
[10] |
Power Supply |
||||||||||||||||||||||||||||||||
10 |
1.0 MPa (DN200 --- DN1400) |
A |
85---265 VAC /45---63Hz |
||||||||||||||||||||||||||||||||
16 |
1.6 MPa (DN50 --- DN600) |
D |
16---36 VDC |
||||||||||||||||||||||||||||||||
20 |
ANSI 150 (DN15 --- DN600) |
B |
Battery Powered |
||||||||||||||||||||||||||||||||
40 |
4.0 MPa (DN 50 --- DN150) |
|
|||||||||||||||||||||||||||||||||
50 |
ANSI 300 (DN50 --- DN600) |
[11] |
Output and Input |
||||||||||||||||||||||||||||||||
J1 |
JIS 10K (DN50 --- DN300) |
0 |
Basic Configuration(current+pulse+alarm) |
||||||||||||||||||||||||||||||||
J2 |
JIS 20K (DN50 --- DN300) |
2 |
Basic Configuration + RS232 |
||||||||||||||||||||||||||||||||
AA |
Special |
4 |
Basic Configuration + RS485 |
||||||||||||||||||||||||||||||||
BB |
Pluggable with Remote Converter |
M |
Basic Configuration + MODBUS |
||||||||||||||||||||||||||||||||
|
H |
Basic Configuration + HART |
|||||||||||||||||||||||||||||||||
[3] |
Installation Type |
P |
Basic Configuration + Profibus-DP |
||||||||||||||||||||||||||||||||
1 |
Fixed Size RBEF-I-A |
S |
Special |
||||||||||||||||||||||||||||||||
2 |
On line Pluggable RBEF-I-B-500 |
|
|||||||||||||||||||||||||||||||||
3 |
On line Pluggable RBEF-I-B-900 |
[12] |
Special Function |
||||||||||||||||||||||||||||||||
4 |
On line Pluggable RBEF-I-B-1200 |
0 |
No |
R |
IR Remote |
||||||||||||||||||||||||||||||
5 |
On line Pluggable RBEF-I-B-1500 |
T |
Power off timer |
H |
Cumulative hours |
||||||||||||||||||||||||||||||
|
Q |
Quantitative control |
J |
Relay Output |
|||||||||||||||||||||||||||||||
[4] |
Electrode material |
|
|||||||||||||||||||||||||||||||||
1 |
316L Stainless Steel [316L] |
[13] |
Factory Calibration |
||||||||||||||||||||||||||||||||
2 |
Hastelloy C [Alloy-C22] |
1 |
3-point calibration,1.5% |
||||||||||||||||||||||||||||||||
3 |
Hastelloy B [Alloy-B10] |
2 |
5-point calibration,1.5% |
||||||||||||||||||||||||||||||||
4 |
titanium |
T |
Other |
||||||||||||||||||||||||||||||||
5 |
tantalum |
|
|||||||||||||||||||||||||||||||||
|
[14] |
Additional No. |
|||||||||||||||||||||||||||||||||
[5] |
Grounding and Lining Protection |
0 |
No |
||||||||||||||||||||||||||||||||
0 |
The Probe Grounding |
|
|||||||||||||||||||||||||||||||||
|
[15] |
Probe Material(PEEK) |
|||||||||||||||||||||||||||||||||
[6]
|
Fluid Temperature |
1 |
SS304 |
||||||||||||||||||||||||||||||||
A |
≤80 ℃ |
2 |
SS316 |
||||||||||||||||||||||||||||||||
B |
≤120 ℃ |
3 |
Ti |
||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
Sample : DN150、4.0MPa、Fixed size type、316L electrode、The Probe Grounding、fluid type≤120℃、IP67、No-exproof 、Compact、220VAC、Basic Configuration +RS485、no special function、3-point calibration、1.5%、no additional demand; proble material: SS304; Model:RBEF-I-15040110B21CA40101 |
The Insertion type electromagnetic flow meter is a cost-saving and space-saving solution for most cases in which the velocity of liquid are needed.
such as water piping, flow switch, leakage detection, network analysis, open channel measurement, etc.
Catalog- Insertion Magnetic flow meter
Manual- Insertion Magnetic flow meter
Other Files - Insertion Magnetic flow meter
Magmeters
Ultrassonic Flow Meter
Coriolis Mass Flow Meter
Other Flow Instrument