Inline Ultrasonic Flow Meter

Inline (Flanged) type Ultrasonic Flow Meter uses transit-time ultrasonic technology in which the signal is transmitted and received alternately between 2 flow sensors and the “time of flight” determines the flow rate. Applications include both commercial and consumable water measurement. Long-term stability and a wide measurement range make it possible not only to measure water consumption, but also to monitor systems for water leakage.

 

Description

  • Principle
  • Features
  • Specification
  • Model Selection
  • Applicants
  • Download
Principle

Measuring principle of Transit-time Ultrasonic Water Flowmeters

RBFM Series Inline  transit time water flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method in which case the ultra sound transverses the pipe twice, or W-method in which case the ultra sound transverses the pipe four times, or in Z-method in which case the transducers are mounted on opposite sides of the pipe and the ultra sound transverses the pipe only once. The selection of mounting method depends on pipe and liquid characteristics. When the flow meter works, the two transducers transmits and receives ultrasonic signals amplified by multi beam which travels firstly downstream and then upstream (Figure 1). Because  ultra sound travels faster downstream than upstream, there will be a difference of time of flight(△t). When the flow is still, the time difference(△t) is zero. Therefore, as long as we know the time of flight both downstream and upstream, we can work out the time difference, and then the flow velocity (V) and flow volume (Q) via the following formula.

 

 V= K*D*                

V: Liquid velocity

K: Constant

D: Distance between the two transducers

△t: Difference in time of flight

Features

RBFM Flanged Type (Inline) Ultrasonic Flow Meters Features:

  • Calibrated in manufacture's lab, field setup is unnecessary.
  • Measurement is independent of fluid nature with wider applications than magnetic meters.
  • Available including up to 2GB event data logger, can search the event of totalizer flow, flow rate, velocity etc.
  • Parallel operation of positive, negative and net flow totalizer, while the output of totalizer pulse and frequency output are transmitted via open collector.
  • Re-calibration or maintenance is easy, no processing interruption (just plug out the inserted transducers from pipe line, when re-calibration or maintenance is finished), can be hot-tapped
  • Inline Ultrasonic Flow Meter


Specification

Pipe Size

(mm)

Pressure

(MPa)

Length

(L)

Flanged Outer D.

D1

Screw D * quantity

Seal Face

Flanged Thickness

D2

f

DN50 

1.6 

280 

165 

125 

18×4 

99 

3 

20 

DN65 

1.6 

200

185 

145 

18×4 

118 

3 

w20 

DN80

1.6

225

200

160

18*4

132

3

22

DN100

1.6

220

220

180

18*8

156

3

22

DN125

1.6

275

250

210

18*8

184

3

22

DN150

1.6

300

285

240

22*8

211

3

24

DN200

1.6

350

340

295

22*12

266

3

24

DN250

1.6

450

405

355

26*12

319

3

26

DN300

1.6

500

460

410

26*12

370

4

28

DN350

1.0

550

505

460

26*16

428

4

30

DN400

1.0

600

565

515

26*16

482

4

30

DN450

1.0

700

615

565

26*20

532

4

30

DN500

1.0

800

670

620

26*20

585

4

32

DN600

1.0

1000

780

725

30*20

685

5

36

DN700

0.6

1100

860

810

26*24

772

4

40

DN800

0.6

1200

975

920

30*24

878

4

44

DN900

0.6

1300

1075

1020

30*24

9781

4

48

DN1000

0.6

1400

1175

1120

30*28

1078

4

52

Model Selection

RBFM Flanged Type (Inline) Ultrasonic Flow Meters Model Selection:

 

RBFM 

X

 

X

X

DNxx

X

X

 

X

X

X

 

 

Instrument Type

 

 

F

Ultrasonic Flow meter

H

Ultrasonic Heat meter

 

Power supply

A

85 to 265VAC

D

24VDC

B

Battery

 

Flow/Heat meter Type

 

F

Flanged type

 

  

  

  

Transducer Type

 
 

50

 

 

65

 

80

 

100

 

125

 

150

 

200

 

250

 

300

 

350

 

400

 

450

 

500

 

600

 

700

 

800

 

900

 

1000

 

 

Pt100

Temperature sensor

 

 

DNxx

Pipe size

  

 

 

Pipe material

  

 

C

Carbon Steel

SS

Stainless Steel

X

Others,  clarify

 

X

Pressure(MPa)

 

 

Output

 

N

NO

A

4-20mA

P

Pulse

R

Relay

2

RS232

4

RS485

5

Datalogger

 

Input

 

N

NO

1

1*4-20mA

2

2*4-20mA

3

3*4-20mA

 

Cable length

X

meter

 

Applicants

RBFM Flanged Type (Inline) Ultrasonic Flow Meters Applications

  • water metering
  • water supply
  • Irrigation meters
  • Water / Wastewater Treatment
  • HVAC/Energy Monitoring 
  • Industries
    Building Automation / HVAC