RBBW DN50-1000 District Ultrasonic Water Meter(Bulk Water Meters) is an innovative flow meter with static flow sensor based on the ultrasonic measuring principle. RBBW Ultrasonic Water Meter utilizes ultrasonic measuring methodology and microprocessor technology. All calculation and flow measuring circuits are designed on one single board, thus offering exceptional accuracy and reliability.
RBBW Series Inline transit time water flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method in which case the ultra sound transverses the pipe twice, or W-method in which case the ultra sound transverses the pipe four times, or in Z-method in which case the transducers are mounted on opposite sides of the pipe and the ultra sound transverses the pipe only once. The selection of mounting method depends on pipe and liquid characteristics. When the flow meter works, the two transducers transmits and receives ultrasonic signals amplified by multi beam which travels firstly downstream and then upstream (Figure 1). Because ultra sound travels faster downstream than upstream, there will be a difference of time of flight(△t). When the flow is still, the time difference(△t) is zero. Therefore, as long as we know the time of flight both downstream and upstream, we can work out the time difference, and then the flow velocity (V) and flow volume (Q) via the following formula.
V= K*D* △t
V: Liquid velocity
K: Constant
D: Distance between the two transducers
△t: Difference in time of flight
District Ultrasonic Bulk Water Meters (DN50 to DN1000) Features:
RBBW District Ultrasonic Bulk Water Meters (DN50-1000) Specification:
DN mm |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
350 |
400 |
500 |
600 |
|||||
Q4 m3/h |
31.25 |
50 |
78.75 |
125 |
200 |
312.5 |
500 |
787.5 |
1250 |
1250 |
2000 |
3125 |
5000 |
|||||
Q3 m3/h |
25 |
40 |
63 |
100 |
160 |
250 |
400 |
630 |
1000 |
1000 |
1600 |
2500 |
4000 |
|||||
Q2 m3/h |
0.1 |
0.16 |
0.252 |
0.4 |
0.64 |
1 |
1.6 |
2.52 |
4 |
4 |
6.4 |
10 |
16 |
|||||
Q1 m3/h |
0.063 |
0.1 |
0.158 |
0.25 |
0.4 |
0.6255 |
1 |
1.575 |
2.5 |
2.5 |
4 |
6.25 |
10 |
|||||
Staring flow |
0.01 |
0.02 |
0.03 |
0.05 |
0.08 |
0.1 |
0.2 |
0.3 |
0.4 |
0.6 |
0.75 |
1.2 |
1.8 |
|||||
L mm |
200 |
200 |
225 |
250 |
250 |
300 |
350 |
450 |
500 |
500 |
600 |
600 |
800 |
|||||
L1 mm |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
120 |
|||||
B mm |
172 |
190 |
205 |
230 |
250 |
285 |
340 |
405 |
460 |
520 |
580 |
715 |
840 |
|||||
D mm |
165 |
185 |
200 |
220 |
250 |
285 |
340 |
405 |
460 |
520 |
580 |
715 |
840 |
|||||
H1 mm |
65 |
70 |
90 |
100 |
125 |
130 |
170 |
203 |
230 |
260 |
290 |
358 |
420 |
|||||
H mm |
245 |
250 |
275 |
290 |
380 |
400 |
470 |
530 |
580 |
640 |
695 |
815 |
925 |
|||||
W mm |
123 |
|||||||||||||||||
n x ∮D1 |
4 *∮18 |
8*∮18 |
8*∮22 |
12*∮22 |
12*∮26 |
16*∮26 |
16*∮30 |
20*∮33 |
20*∮36 |
|||||||||
Q3/Q1 |
400:1 (100:1; 160:1; 250:1; 500:1 optional) |
|||||||||||||||||
Working pressure |
1.6MPa(other can be customized) |
|||||||||||||||||
Pressure lose |
⊿p25 |
⊿p10 |
||||||||||||||||
Channel |
2-channel |
3-channel |
||||||||||||||||
Max volume (m3) |
99999999.99999 |
|||||||||||||||||
Accuracy class |
Class 2 |
|||||||||||||||||
IP grade |
IP68 |
|||||||||||||||||
Medium temperature |
T30,T50,T70 (T30 default) |
|||||||||||||||||
Power supply |
3.6V lithium Battery(24DC, 220VAC customized) |
|||||||||||||||||
Battery Lifetime |
≥10 years |
≥DN250 ≥6 years |
||||||||||||||||
Installation |
At any angle |
|||||||||||||||||
IP Grade |
IP68; IP65 for 24DC, 220VAC |
|||||||||||||||||
Environment class |
Class C ( Class B and I for optional) |
|||||||||||||||||
Electromagnetic class |
E1 |
|||||||||||||||||
Medium |
Conduit is fully charged with water |
|||||||||||||||||
Remark:
District Ultrasonic Water Meter Model Selection:
RBBW(DN50-1000) Ultrasonic Water meter |
|||||||||
RBBW |
X |
X |
DN-X |
X |
|
X |
X |
|
|
|
Transducer Channel |
||||||||
|
D |
Single-channel(DN15-300) |
|||||||
|
M |
Multi-channel(DN50-300) |
|||||||
|
|
Temperature |
|||||||
|
|
N |
Normal temperature: 4-50℃ |
||||||
|
|
H |
High temperature:4-100℃ |
||||||
|
|
|
Pressure Range |
||||||
|
|
|
16 |
1.6 MPa |
|||||
25 |
2.5MPa |
||||||||
S |
Special, pls clarify |
||||||||
|
|
|
|
Power supply |
|||||
|
|
|
|
B |
Battery Supply |
||||
DC |
24VDC |
||||||||
AC |
95-265VAC |
||||||||
|
|
|
|
|
Communication type |
||||
|
|
|
|
|
MW |
Wired M-bus |
|||
|
|
|
|
|
LM |
Wireless M-Bus(Testing) |
|||
|
|
|
|
|
2 |
RS485(Modbus protocol) |
|||
S |
Special, pls clarify |
||||||||
|
|
|
|
|
|
Connection Type |
|||
|
|
|
|
|
|
C |
Copper |
||
|
|
|
|
|
|
D |
DIN (En13757) |
||
|
|
|
|
|
|
A |
ANSI |
||
|
|
|
|
|
|
S |
Special |
||
|
|
|
|
|
|
|
|
Pipe material |
|
|
|
|
|
|
|
|
|
C |
Cast iron |
|
|
|
|
|
|
|
|
S |
Stainless Steel |
Remark:
District Ultrasonic Water Meter Typical Application
Catalog - District Ultrasonic Water Meter
Manual - District Ultrasonic Water Meter
Other Files - District Ultrasonic Water Meter
Magmeters
Ultrassonic Flow Meter
Coriolis Mass Flow Meter
Other Flow Instrument