High Pressure Magnetic Flow meter(Magmeters) is designed to measure the flow rates of conductive liquids in applications with high operating pressures.
It can be used in applications with pressures in excess of 6000 psig (42 Mpa), Line sizes ranging from 1" to 8" (25 mm to 200 mm) can be accommodated by the high pressured mag meter, with available process connections including ANSI, DIN, and JIS-type flanges.
A wide selection of options are also available for the display/converter module including Compact or remote type, 85-265 VAC or 16-36 VDC power, and HART, RS485 and Profibus communications.
High Pressure Magnetic flow meter Features:
High Pressure Magnetic Flow Meter(Magmeters) Specification:
Specification |
Data |
Specification |
Data |
Flow range |
0-12m/s |
Medium |
Conducting medium(Solid content ≤5%) |
Measuring repeatability |
± 0.1% |
Electrical Conductivity |
>5us/cm(water >20us/cm) |
Accuracy |
±0.5% |
Power |
220VAC/50Hz |
Pressure |
26MPa |
24VDC |
|
32MPa(special order) |
Output |
4-20mA |
|
Operation temp. |
0 to +80℃ |
Pulse |
0-1kHz(Adjustable) |
0 to + 45℃ |
Consumption |
10VA |
Dimensions
Pipe Size |
Working Pressure(MPa) |
a |
b |
c |
d |
Screw Size |
50 |
26 |
325 |
234 |
165 |
215 |
M24*8 |
65 |
26 |
330 |
256 |
190 |
246 |
M27*8 |
80 |
26 |
430 |
276 |
203 |
265 |
M30*8 |
100 |
26 |
440 |
308 |
241 |
310 |
M33*8 |
125 |
26 |
505 |
356 |
292 |
375 |
M39*8 |
Remark: 1. a is meter'length; b is Flange outside diameters; c is flange inside diameters; d is length of Magnetic Converter base to botton of pipe.
High Pressure Magnetic Flow Meter Model Selection
1 Nominal Diameter(mm)/ [inches] (1)
|
|||||||||||||||||||||||
2 Flange Rating (1)
|
|||||||||||||||||||||||
3 Electrode Material
|
|||||||||||||||||||||||
4 Lining Material
|
|||||||||||||||||||||||
5 Grounding and Lining Protection
|
|||||||||||||||||||||||
6 Max. Process Temperature
|
|||||||||||||||||||||||
7 Environmental Protection Class
|
|||||||||||||||||||||||
8 Explosion Proofing
|
|||||||||||||||||||||||
9 Configuration – sensor/transmitter
|
|||||||||||||||||||||||
10 Power Supply
|
|||||||||||||||||||||||
11 Display and Programming
|
|||||||||||||||||||||||
12 Output and Input
|
|||||||||||||||||||||||
|
|||||||||||||||||||||||
13 Calibration Specification
|
|||||||||||||||||||||||
14 Flow Tube Configuration
|
High Pressure Magnetic Flowmeter (Magmeters)Typical applications:
Water & Wastewater industry
Pulp Paper & Power Generation industry
Irrigation System
Leakage Detection
HVAC Building Automation System
Smart Metering
Chemical Industry & Refinery Petrochemical industry
Food and Beverage industry