Magnetic Flowmeters

 

RBEF Electromagnetic Flow meter is suitable to measure volumetric flow rate of the conductive liquid and slurry in the closed pipe, e.g. clean water, sewage, various solutions of acid, alkali, salt; slurry, slag, pulp and other liquids such as food-beverage etc. 

 As a professional supplier and manufacturer of Electromagnetic Flow Meter, RB flowmeter has been supplying quality Electromagnetic Flow Meter to customers all over the world for over 16 years.

A various type Magnetic Flow meters can provide as follows:

  •  Standard Magmeters are for most of water and wastewater applications.
  • Ceramic liner Magnetic Flow Meter for Highly resistant Magmeter liner and electrodes that are suitable for most extreme process media, pipe size is from DN25 to DN200.
  • Sanitary Type Magnetic Flowmeters are designed for the food & beverage and pharmaceutical industries and is available with hygienic and flexible process connections, pipe size is from DN10 to DN150.
  • High frequency Emag flow meter for Slurry and High Percentage of Solids, etc.

Description

  • Features
  • Specification
  • Model Selection
  • Applicants
  • Download
Features

RBEF Emag meter Features

 

Available Sizes

ISO: DN15…DN3000

US: 1/2”…118”

Accuracy

Standard: ±0.5% (0.6m/sec to 15 m/sec)

Optional: ±0.2% (1.0m/sec to 15 m/sec)

Measurement Range

Up to: 381,704 m3/hr

1,727,305 gal/min

Maximum Flow Velocity

12m/sec

Measurement Resolution

±1mm/sec

Turndown

Up to 1500:1

Process Connections

GB Flange

JIS Flange

DIN Flange (DIN 2501)

ANSI Flange (B16.5)

Wafer Design

Lining Materials

Neoprene

PTFE

Polyurethane

PFA

Tefzel

(PFA and Tefzel lining available with wire net reinforcement for negative pressure applications)

Ceramic

Electrode Materials

316L Stainless Steel

Hastelloy-C22

Hastelloy-B10

Titanium

Tantalum

Platinum/iridium Alloy

Tungsten Carbide Coated 316L Stainless Steel

Ceramic

Removable Electrode

In-situ Electrode Maintenance and Replacement Option Available

Housing Protection Class

IP65

IP67 (Compact versions only)

IP68 (Remote Versions Only)

Remote Transmitter

Pipe Mount or Wall Mount

Available Power Supplies

85…265VAC

16…36VDC

Transmitter Configuration Options 

Front Panel Keypad

Hand Held Infrared Programmer

Output Signals

1 x Active Current Output

1 x Passive Current Output

1 x Frequency / Pulse Output

Status Outputs

2 x Contact / Status Outputs for Upper and Lower Flow Limit

Digital Communication

RS485 Modbus, GPRS

Specification

RBEF Magmeters Specifications

Sizes

Flanged (Metric)

DN15…DN3000

Flanged (US)

1/2”… 118”

Wafer Design

DN15…DN100

Nominal Pressure

GB,JIS and DIN Flange

0.6 MPa, 1.0 MPa, 1.6 MPa, 4.0 MPa

ANSI Flange

Class 150, Class 300

Wafer Design

1.6 MPa, 4.0 MPa

For additional pressure requirements, please contact manufacturer

Accuracy (pulse output)

Standard

±0.5% (0.6m/sec to 12 m/sec)

Optional

±0.2% (1.0m/sec to 12 m/sec)

Measurement Resolution

±1mm/sec

Max Flow Tube Velocity

SI:

49 ft/s

US:

12 m/s

Ambient Temperature

-25…+55°C   /   -13…+131°F

Relative Humidity

5%…90%

Conductivity

≥5 μS/cm

Transmitter Mounting Availability

Compact type 

Sizes: DN15…DN1000

1/2”…40”

Remote type 

Sizes: DN15…DN3000

1/2”… 118”

Note 1: Cable between flow tube and remote transmitter is type SMFE100

Note 2: Remote unit supplied with 10m cable as standard

Note 3: Max cable length is 200m (650ft)

 

Material

SI

US

Liner Material Options

Neoprene (std)

DN15…DN3000

1/2”…56”

PTFE

DN15…DN1000

1/2”…40”

Polyurethane

DN15…DN300

1/2”…12”

PFA

DN15…DN250

1/2”…10”

PFA with optional wire reinforcement

DN80…DN250

3”…10”

Tefzel

DN15…DN250

1/2”…10”

Tefzel with optional wire reinforcement

DN80…DN250

3”…10”

 

ceramic liner and electrodes

DN15…DN200

1/2”…8”

Electrode Material Options

316L stainless steel (std)

DN15…DN3000

1/2”…56”

Hastelloy – C22

DN15…DN1000

1/2”…40”

Hastelloy – B10

DN15…DN1000

1/2”…40”

Titanium

DN15…DN250

1/2”…10”

Tantalum

DN15…DN250

1/2”…10”

Platinum/iridium Alloy

DN15…DN250

1/2”…10”

316L with tungsten carbide coating

DN15…DN600

1/2”…24”

Grounding Options

Flange Grounding

DN15…DN3000

1/2”…56”

Grounding Ring

DN15…DN250

1/2”…10”

Electrode Grounding

DN50…DN3000

2”…56”

Inlet protection ring

DN50…DN300

2”…12”

 

Type

Liner

Standard

Optional

Max Process Temperature Limits

Compact

Neoprene

80°C / 176°F

120°C / 248°F

PTFE

80°C / 176°F

120°C / 248°F

Polyurethane

80°C / 176°F

-

PFA

80°C / 176°F

120°C / 248°F

Tefzel

80°C / 176°F

-

Remote

Neoprene

80°C / 176°F

120°C / 248°F

PTFE

80°C / 176°F

120°C / 248°F

180°C / 356°F

Polyurethane

80°C / 176°F

-

PFA

80°C / 176°F

120°C / 248°F

Tefzel

80°C / 176°F

-

Environmental Protection Class

Compact

IP 65

IP67

Remote

IP 65

IP 68

Power Supply Options

85…265VAC / 45…63Hz, 20VA

16…36VDC, 16VA

Display

2 or 3 line backlit LCD

Configuration Access

Front panel keypad

Hand held infrared remote control (optional)

Output Signals

Active analog current output

Max load resistance 0…1.5kΩ for 0…10mA

0…750Ω for 4…20mA

Accuracy = same as pulse output ±0.1% of rate

Option: HART Protocol

Passive analog current output 

Requires 24Vdc external supply to operate

Accuracy = same as pulse output ±0.1% of rate

Pulse / frequency and alarm outputs

Optically isolated open collector output powered either internally or externally

  Int. power:  28VDC with 1.2kΩ pull-up resistor

  Ext. power:  ≤36VDC, max current 250mA

Digital Communications

RS485 Modbus

GPRS (superimposed on current output)

All interfaces have built in lightning protection

Electrical isolation

Isolation between all I/O and input power no less than 500V

Isolation between all I/O and ground no less than 500V

Isolation between flow tube and transmitter outputs no less than 500V

Standard

JB/T 9248-1999 Electromagnetic Flow meter

(1) Line size selection will be inches for ANSI Class 150/300 rating selection, DIN size for all other ratings

(2) Order longer cable length separately

(3) Ceramic liner and electrodes is with wafer type only

Model Selection

RBEF Magnetic Flow Meter Model Selection

RBEF-

DN

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

 

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

13

 

14

15

 

1 Nominal Diameter(mm)/ [inches] (1)

0015 [½”]

0100 [4”]

0450 [18”]

1400 [56”]

0020 [¾”]

0125 [5”]

0500 [20”]

1600

0025 [1”]

0150 [6”]

0600 [24”]

1800

0032 [1¼]

0200 [8”]

0700 [28”]

2000

0040 [1½]

0250 [10”]

0800 [32”]

2200

0050 [2”]

0300 [12”]

0900 [36”]

2400

0065 [2½]

0350 [14”]

1000 [40”]

2600

0080 [3”]

0400 [16”]

1200 [48”]

3000

 

 

 

 

 

2 Flange Rating (1)

02

0.25 MPa

1600 … 3000

06

0.6 MPa 

700 … 3000

10

1.0 MPa 

200 … 1400

16

1.6 MPa 

15 … 600

20

ANSI Class 150

15 …1400

40

4.0 MPa 

15 … 150

50

ANSI Class 300

15 … 1400

AA

Special

 

 

 

 

 

3 Electrode Material

1

316L Stainless Steel

3

Hastelloy C-22

4

Hastelloy B-10

5

Titanium

6

Tantalum

7

Platinum / Iridium Alloy

8

Tungsten Coated Stainless Steel

9

ceramic

 

 

 

4 Lining Material

1

Neoprene (Hard rubber)

≤ 3000

2

PTFE

≤ 1000

3

Polyurethane

≤ 300

4

PFA

≤ 250

5

Tefzel

≤ 250

6

PFA with Wire Net

80 … 250

7

Tefzel with Wire Net

80 … 250 

8

Ceramic

15 … 200

 

 

 

 

5 Grounding and Lining Protection

0

Flange ground

15 … 3000

1

Earth ring

15 … 250

 2

Ground electrode

50 … 3000

3

Inlet protection ring

50 … 3000

 

 

 

 

6 Max. Process Temperature

A

80°C

All Linings

B

120°C

Neoprene / PTFE / PFA / Tefzel

C

180°C

PTFE only

 

 

 

 

 

 

 

 

 

7 Environmental Protection Class

1

IP65

2

IP67 (Compact Type Only)

3

IP68 (Remote Type Only)

 

 

 

8 Explosion Proofing

1

None

2

Ex DE IIC T6

 

 

 

9 Configuration – sensor/transmitter 

1

Compact (15 … 1000)

2

Remote (with 10m cable)(2)

3

Wafer

 

 

 

10 Power Supply

A

AC: 85 … 265 VAC / 45 … 63Hz

D

DC: 18 … 36 VDC

 

 

 

11 Display and Programming

2

2 line LCD display + keypad programming

3

3 line LCD display + keypad programming

 

 

 

12 Output and Input

0

Basic Configuration (current, pulse and contact outputs)

2

Basic Configuration + RS485

3

Basic Configuration + GPRS

4

Basic Configuration + MODBUS

 

 

 

 

13 Calibration Specification

1

3 point, 0.5% accuracy

2

3 point, 0.25% accuracy

3

Special

 

 

 

14 Flow Tube Configuration

1

Flange Type

15 … 3000

D

DIN

 

A

ANSI

 

O

Others(pls clarify)

 

2

Flange type with removable electrodes

15 … 3000

3

Flange material

 

C

Carbon Steel

 

S

304 Stainless Steel

 

 

 

 

 

15 Special Function

0

No

R

IR Remote

T

Power off timer

H

Cumulative hours

Q

Quantitative control

J

Relay Output

Remark:

(1) Line size selection will be inches for ANSI Class 150/300 rating selection, DIN size for all other ratings

(2) Order longer cable length separately

(3) Ceramic liner and electrodes is with wafer type only

Applicants

The RBEF electromagnetic flow meter (Emag. meters) range is designed to measure the volumetric flow of conductive liquids and slurries within closed pipelines in industries such as water & wastewater, chemical, petroleum, metal production, power, pharmaceutical, food & beverage, pulp & paper, etc. 

The RBEF is the ideal instrument for :

  • Water and wastewater Municipal projects
  •  Measuring and billing in civil, industrial and agricultural sector;
  • For flow measurement in residual water treatment.
  •  Chemicals, acids, alkalis fluids; Paint
  • Viscous fluids and slurries
  • Water & wastewater flows
  • Irrigation meters of Agriculture
  • Leakage Detection 
  • Pulp and slurries
  • Beverage and pharmaceutical industries

Note: The minimum conductivity of the measured flow must be ≥ 5μS/cm for the meter to function correctly.

RBEF Electromagnetic Flowmeter Application Worksheet

RBEF

Flow meter Application Worksheet

(Electromagnetic flow meter)

Customer Name

 

Contact

 

Tel/Fax/Email

 

Project Name

 

 

Tag.No

 

 

 

Process Parameters

Pipe Spec / Material

 

 

Process Connection

 

 

Fluid Type

 

 

Max Flow 

 

 

Nor. Flow 

 

 

Min. Flow 

 

 

Fluid Temperature

 

 

Operating Pressure

 

 

Measuring range

 

 

Power Supply

85 --- 265 VAC or 16 --- 36 VDC

 

Accuracy % required

( ±0.5 or ±0.2 )

 

 

Manufacturers Configuration Sheet

Nominal Diameter mm

 

 

Nominal pressure  MPa

 

 

Electrode Material

 

 

Lining Material

 

 

Grounding/

Protection

 

 

Temperature Rating

 

 

IP Protection Class

 

 

EX Certification

 

 

Configuration

Compact or Remote

 

Power Supply

85 --- 265 VAC or 16 --- 36 VDC

 

Programming Display

 

 

Input/output signal

 

 

Inspection

 

 

Connection type

 

 

Electric connection

 

 

Special signal cable

 

 

Mating Flange Set

 

 

Accessory 1

 

 

Accessory 2

 

 

Model Number

RBEF-

 

Remark

 

 

 

 

Download

product search